        MC093S Microwave Motion Sensor 198-264V AC 50Hz

        Basic Information
        Place of Origin: China
        Brand Name: Merrytek
        Certification: CE/RED
        Model Number: MC093S
        Minimum Order Quantity: 100pcs
        Price: Negotiation
        Packaging Details: Bubble bag + partition + outer box (K=A)
        Delivery Time: within 5 working days for sample and small order; within 3-4 weeks for bulk order
        Payment Terms: T/T, Western Union
        Supply Ability: 10,000pcs per Month
        Contact Now
        Detail Information
        Operating Voltage Range: 198-264V AC 50Hz Stand-by Power: ≤0.5W
        Operating Frequency: 5.8 GHz ±75 MHz. Hold Time: 5S/30S/60S/3Min/5Min/10Min/20Min/30Min(adjust By 3 DIP Switches)
        Detection Area: 100%/75%/50%/25% (adjust By 2 DIP Switches) Detecting Radius: 4-6M (mounted At 3M Height)
        Mounting Height: Supportable Installation Height: 2.5-6m, Maximum Induction Distance Installation Height: 2.5m

        Product Description

        Microwave Motion Sensor Human Sensor for Accurately Detecting with Patented Low Impedance Antenna MC093S

         


        1. Features
         

        1) Built-in daylight sensor and human sensor, which can automatically switch on/off based on ambient light and human motion.

        2) Using the latest human detection technology to detect small movements such as shaking head, turning around and etc. suitable for office field.

        3) Patented low impedance antenna design, anti air conditioning, ventilator and other interference;

        4) Support for different kind of application way.

        5) Override sensor function by switch on and off power 3 times

        6) DIP Switch design, users can configure the parameters according to their needs.


         

        2. Parameters

         

        Input Operating Voltage 198-264V AC 50Hz
        Rated Voltage 220-240V AC 50Hz
        Stand-by Power ≤0.5W
        Surge Test Between L and N: 1KV
        Output Working Mode ON/OFF
        Type of Load Resistive or Inductive
        Load Capacity 800W (Resistive) or 400W (Inductive)
        Max. Surge Capacity

        30A (50% Ipeak, twidth =500uS, 230Vac full load, cold start)

        60A (50% Ipeak, twidth =200uS, 230Vac, full load, cold start)

        Sensor Parameters Operating Frequency 5.8 GHz ±75 MHz.
        Transmitting power 0.3mW Max.
        Hold time 5S/30S/60S/3Min/5Min/10Min/20Min/30Min(adjust by 3 DIP Switches)
        Detection Area 100%/75%/50%/25% (adjust by 2 DIP Switches)
        Daylight Sensor 25lux/50lux/100lux/300lux/Disable(adjust by 4 DIP Switches)(Diffusion state)
        Detecting Radius 4-6M (mounted at 3M height) (see Note 2)
        Mounting Height Supportable installation height: 2.5-6m maximum induction distance installation height: 2.5m
        Detecting Angle Ceiling mount 150°

        Operating

        Environment

        Operating Temperature -25℃…+60℃
        Storage Temperature -40℃…+80℃; Humidity: 10%-95% (non-condensing)
        Certificate Standards Safety standards EN61058-1
        EMC standards EN300440 EN301489-1 EN55015 EN61547 EN61000-3-2 EN61000-3-3 EN62479
        Environmental Requirement Compliant to RoHS
        Certificate CE RED
        Others Input/output terminal screw terminal block Wire diameter:0.75-1.5mm2
        IP Rating IP20
        Protection Class Class II
        Installation Built-in installation
        Dimension 65*65*28mm
        Package Bubble bag + partition + outer box (K=A)
        Net Weight 59±2g
        Lifetime 50,000h @ Ta Full load

        Note

        1. “N/A”means not available.

        2. the induced distance is related to the moving speed and volume of moving objects. This data is obtained from the personnel test of 170 cm high moving speed of 0.3 m/s.

         

        3.Function

        1) On/OFF Function

         

        MC093S Microwave Motion Sensor 198-264V AC  50Hz

         

        MC093S Microwave Motion Sensor 198-264V AC  50Hz

                                                                              

         
        4.Dimension (mm)
         
        MC093S Microwave Motion Sensor 198-264V AC  50Hz

        *The sensor is designed for connect one load only. Connect more than one loads may damage the sensor.
         

        5.Installation guide:


         

        For panel light (cut size of 40*40mm) For ceiling lamp

        MC093S Microwave Motion Sensor 198-264V AC  50Hz

        MC093S Microwave Motion Sensor 198-264V AC  50Hz

         

         Top mounting(cut size of 40*40mm)

        MC093S Microwave Motion Sensor 198-264V AC  50Hz

        Base mounting

        MC093S Microwave Motion Sensor 198-264V AC  50Hz

         

         
        6.Function diagram
        MC093S Microwave Motion Sensor 198-264V AC  50Hz
         
        7.Wiring

        MC093S Microwave Motion Sensor 198-264V AC  50Hz

        *The sensor is designed for connect one load only. Connect more than one loads may damage the sensor.
         
        8. Radiation pattern

        1)Ceiling mounting

         

        MC093S Microwave Motion Sensor 198-264V AC  50Hz

        MC093S Microwave Motion Sensor 198-264V AC  50Hz

         

        9. DIP switch

        1)Detection Area

         

          1 2  
        ON ON 100%
        - ON 75%
        ON - 50%
        - - 25%
         

        2) Hold Time

          3 4 5  
        ON ON ON 5S
        ON - ON 30s
        ON ON - 1min
        ON - - 3min
        - ON ON 5min
        - - ON 10min
        - ON - 20min
        - - - 30min
         
        * Note: For better minor motion detection ,it’s recommend to set the hold time above 3 min
         

        3) Daylight Sensor

          6 7 8  
        ON ON ON 25Lux
        ON ON - 50Lux
        ON - - 100Lux
        - ON ON 300lux
        - - - Disable
         

        4) Minor motion indicator

          9  
        ON Turn on
        - Turn off
         

        10. Cancel sensor function

        Sensor function can be canceled by switch on /off power 3 time in 2s, Turn on the power again, sensor function come back .

         

        11. Initialization

        After power on, the sensor automatically turns on light at 100% brightness. After 30sec, it turns off the light. During the initialization, the sensor is not able to detect movement.

         

        12. Default Settings

        Detection area: 100%, Hold time: 3min, Daylight sensor: Disable ,Minor motion indicator:Turn off

         

        13. Notes for Application

        1), The sensor should be installed by a professional electrician. Please turn off the power before installing, wiring, changing the setting of the DIP switch.

        2), The light sensitivity threshold is in a sunny environment, no shadow and ambient light diffuse reflection.

        Ambient lux level could be different in different environment, weather, climate, time-of-day and season.

        3),The parameters of the sensor may need to be reconfigured in different installation environments.

        4),This sensor is for indoor use only. It will affect the waterproof effect for outdoor use. Wind, rain, and moving objects around will cause false triggering.


         

         

         

        Contact Details
        刘伯温二四六精选免费料

        <button id="jrctm"><acronym id="jrctm"></acronym></button>

        <dd id="jrctm"></dd>
        <button id="jrctm"></button>
            1. <progress id="jrctm"></progress>
              <tbody id="jrctm"><track id="jrctm"></track></tbody>
              <em id="jrctm"><tr id="jrctm"></tr></em>